Two-element InAsSb one-stage thermoelectrically cooled photovoltaic infrared detector with band-pass filters2E-PVA-1TE-5-0.4x0.4-TO39-BPF1-BPF2-70 - Detector in Development
2E-PVA-1TE-5-0.4x0.4-TO39-pAl2O3-BPF1-BPF2-70 is a two-element one-stage thermoelectrically cooled photovoltaic IR detector based on InAsSb heterostructure for optimal performance and stability. Each of the two active elements with active area 0.4 mm × 0.4 mm, is paired with an optical filter, allowing for the selective detection of different gases based on their specific absorption spectra. The detector can be provided in the TO39 package.
Features
Affordable solution for gas sensing
Low crosstalk
One-stage thermoelectrically cooled
Possibility of selecting various configurations of bandpass filters (BPF1-BPF2)
One-element detectors with filters available with a standard lead time
Applications
Gas detection, monitoring and analysis: H2O, C2H2, CH4, C2H6, CO2, N2O, CO
Detector configuration
Detector symbol
|
2E-PVA-1TE-5-0.4x0.4-TO39-pAl2O3-BPF1-BPF2-70 |
|
Detector type
|
photovoltaic |
|
Active element material | epitaxial InAs heterostructure | |
Cooling | 1TE (Tchip≅265K) | |
Temperature sensor | thermistor | |
Number of elements | 2 | |
Active area of single element, A | 0.4 mm × 0.4 mm | |
Active area pitch | 2.0 mm | |
Optical immersion | no | |
Package | 1TE-TO39 (8 pin) | |
Acceptance angle, Φ | ~70 deg. | |
Window | pAl2O3 (planar sapphire) | |
BPF1*) | BPF2730-B150 (detected gas: H2O)
BPF3000-B200 (detected gas: C2H2) BPF3330-B150 (detected gas: C2H4, C2H6) BPF3897-B074 (reference) BPF4260-B160 (detected gas: CO2) BPF4474-B077 (detected gas: N2O) BPF4712-B092 (detected gas: CO) |
|
BPF2*) | BPF2730-B150 (detected gas: H2O)
BPF3000-B200 (detected gas: C2H2) BPF3330-B150 (detected gas: C2H4, C2H6) BPF3897-B074 (reference) BPF4260-B160 (detected gas: CO2) BPF4474-B077 (detected gas: N2O) BPF4712-B092 (detected gas: CO) |
|
*)Available options of band-pass filters (BPF) |
Specification
(Typ.,Tamb = 293 K, Tchip = 265 K, Vb = 0 V)
Parameter | Value |
Unit | |||||||
Filter centre wavelength, λcwl | 2730 | 3000 | 3330 | 3897 | 4260 | 4474 | 4712 | nm | |
Filter bandwidth | 150 | 70 | 150 | 74 | 160 | 77 | 92 | nm | |
Detectivity, D* (λcwl, 20 kHz) |
6.1×109 | 7.7×109 | 8.0×109 | 8.2×109 | 7.7×109 | 7.7×109 | 6.1×109 | cm⋅Hz1/2/W | |
Current responsivity, Ri (λcwl) |
1.15 | 1.45 | 1.50 | 1.55 | 1.45 | 1.35 | 1.15 | A/W | |
Dynamic resistance, Rd | 250 |
Ω |
Spectral response
(Typ., Tamb = 293 K, Tchip = 265 K)
Access to file